Buyhere22, 26 Somers Road, Rugby, CV22 7DH

XYS3580 Digital LCD Programme Step-Up / Down Voltage Regulated PSU Power Supply Module NEW UK

£35.99

3 in stock

XYS3580 Digital LCD Programme Step-up/down Regulated Power Supply Module.
This is the Geniune item NOT A COPY.
This is will be security marked.

 

 

UK STOCK, UK SELLER

 

Made of high quality material, solid, durable and good performance, long service life.
A voltage regulator that no matter the input voltage is lower/higher than output voltage, the output voltage can be stable.
It integrates analog adjustment and digital control, and shows the preset voltage/current/power and so on in real time.
Large high definition LCD with 160°wide viewing angle, easy and comfortable reading.
It features both hardware and software protection, safe to use.
The screen supports 4 way rotation, convenient to use.
It also has night rest screen mode, suitable for any conditions.
Smart temperature control fan, thickened radiator, 2 way ventilation, great cooling effect.
It also can used as a common voltage Buck-Boost power supply with over-voltage/over-current/over power/over temperature/under voltage protection.
With constant current function, it can charge the rechargeable battery within 0.6V-30V.
Boost Step Down Converter only, other accessories demo in the picture is not included!

Specification:
Material: ABS, Electronic Components
Size: app.7.9 x 4.2 x 4.1cm/3.11 x 1.65 x 1.61in
Color: Black
Quantity: 1 Pc

Product Parameters:
Input Voltage: DC 6.0-30V(Limit low voltage 5.5V, limit high voltage 32V)
Output Voltage: DC 0.6-30V
Output Current: 0.000A-5.000A
Output Power: 80W
Input Current Limit: Max.7A
Current Resolution: 0.001A
Voltage Accuracy: ±0.3% + 1 byte
Current Accuracy: ±0.4% + 3 byte
Capacity: 0-999999Ah
Energy: 0-999999WH
Time: 0-1000 Hours
Hardware Protection: Output short circuit protection, short circuit without burning, output anti-backflow, can directly charge the rechargeable battery, without additional anti-backflow diode.
Software Protection: Over voltage protection(OVP), over current protection(OCP), over power protection(OPP), over temperature protection(OTP),input under voltage protection(LVP), power chip self protection(OEP).
Tips: Requirements for full load output power supply: input power supply optional 15-35V, power above 100W

Charging Steps:
1. Determine the floating charge voltage and charging current of your rechargeable battery; (if the parameter of lithium battery is 3.7V/2200mAh, the floating charge voltage is 4.2V; if it is 12V rechargeable battery, generally set the floating charge voltage to about 14V)
2. Under no-load condition, set the output voltage to floating charge voltage; (if 3.7V lithium battery is charged, adjust the output voltage to 4.2V)
3. Set the charging current (constant current value) and set the current directly.
4. Connect the battery for charging.
Tips: When charging the battery, the positive and negative poles of the battery should not be connected reversely, which is easy to burn the product!

To drive the LED lamp:
1. Determine the working current and maximum working voltage of the led you need to drive;
2. Under no-load condition, set the voltage value and current value to make the output voltage reach the maximum working voltage and current of LED (Note: calculate the power when setting the current, charge within the power range, use over power, and the product will enter the protection state.)
3. Connect led and test the machine.
This product can adjust the constant current value (between 0 – working current) to realize the LED’s stepless dimming and no stroboscopic!!

Details of interface and key functions:
Short press the “ON/OFF” button to turn on and off the power output, long press the ” ON/OFF” button for 2 seconds, the screen can rotate, 360 °four-way rotation.Turn the encoding potentiometer to turn the page quickly.
Press the code potentiometer key briefly to activate the parameter (voltage / current) to be set;
Short press the key of the coding potentiometer to switch between full selection and bit selection;
When all is selected, the blue display will be reversed, and the set voltage / current will be switched through the rotary encoder;
After bit selection, the corresponding bit will be displayed in reverse blue, and parameters will be set by rotating encoder;
After the setting is completed, long press the key of the encoding potentiometer for 2 seconds or more, and no key operation will automatically exit the setting;
All parameters are saved automatically after exiting.
Press the encoding potentiometer key for a short time, and select “capacity / energy / time” for all. After selecting all, the corresponding one will be displayed in reverse blue. Switch the parameters to be cleared by rotating the encoder. After selecting, press the encoding potentiometer key for a short time to clear the corresponding parameters. After selecting, press the encoding potentiometer key for a long time for 2 seconds or over 6 seconds, and the operation without keys will exit automatically.

Press the key of coding potentiometer briefly to activate the parameter to be set;
The switch of parameter name and bit selection is realized by short pressing the key of coded potentiometer;
After selecting the parameter name, the parameter name will be displayed in reverse blue, and the parameter to be set will be switched by rotating the encoding potentiometer;
After bit selection, the corresponding bit will be displayed in reverse blue, and parameters will be set by rotating encoder;
After the setting is completed, long press the key of the encoding potentiometer for 2 seconds or more, and no key operation will automatically exit the setting;
All parameters are saved automatically after exiting.

Data Group Function Description:
10 sets of data groups of M0-M9 can be saved. By default, the data group M0 can be saved. Press and hold the key of coding potentiometer for 2 seconds on any interface to quickly call up the M1/M2 data group, and the serial number of the current data group will be displayed at the interface index;
In the power parameter setting interface, select the data group, and rotate the encoding potentiometer to call up the corresponding data group;
After the parameters in the data group are modified and exited, the corresponding parameters will be stored in the current data group by default.
Tips: power output is off by default after data group switching;

Set voltage U-SET:0.6-30V;
Set current I-SET:0-5.1A;
Input undervoltage protection LVP default: 4.8V, self setting;
Output overvoltage protection OVP default: 37V, can be set by itself;
Output over-current protection OCP default: 5.2A, can be set by yourself;
Output over power protection OPP default: 81W, self setting;
Maximum operation time OHP: when the parameter is not set to 0, turn on this function. When the operation reaches the set time, the power will automatically turn off the output;
Maximum capacity OAH: when the parameter is not 0, turn on this function, when the capacity reaches the set parameter, the power will automatically turn off the output;
Maximum energy OWH: when the parameter is not 0, turn on this function, when the energy reaches the set parameter, the power will automatically turn off the output;
OHP/OAH/OWH function can well realize timing/quantitative power supply.

Press the encoding potentiometer key briefly to select / switch the parameters to be set. After selection, the parameters will be displayed reversely, and the parameters will be set by rotating the encoder;
After the setting is completed, long press the key of the encoding potentiometer for 2 seconds or more, and no key operation will automatically exit the setting;
All parameters are saved automatically after exiting.

Note:
No retail package.
Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.
Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!

Package includes:
1 x Boost Step Down Converter

Note:The maximum input voltage is 30V exceeding this voltage WILL permanently damage the item.
If the XYS3580 module is being used to output power for battery charging or capacitive load, it is important that you add a diode on output positive to avoid current flowing back into the the module as this will permanently damage the item.

This is the Geniune item NOT A COPY.
This is will be security marked. Warranty void if removed stickers, because a buyer tried to return a clone back to me!

Important Note Before you decide to Buy: This item is provided with NO instructions or data sheets. We are unable to provide any technical support, it is therefore essential that you have the resources available to make use of this item and how it operates within the electrical specifications. We check and test each item, we are therefore unable to accept any returns based on a faulty module.

This item will be fully tested prior to despatch. Buy with confidence.

Please read and note the following before ordering:
1) My Shipping is for UK Mainland ONLY. No Scotish Highland, Northern Ireland, Isle of Wight or other Isles. Some areas may incur additional costs, if you are unsure please contact me prior to ordering.
2) Please ensure you have a valid contact phone number, I may pass this number onto the Carrier for delivery. No refund for carriage cost will be offered, if delivery is delayed as a result of no valid contact number being provided.
3) I welcome collection for orders,please select collection on checkout otherwise your order will be despatched. Once your order has been picked and tested if applicable. We will then inform you of a date and time for collection. Please bring your payment card for verification when collecting your order. No order will be released without card verification.
4) I am unable to provide ANY technical support, please ensure you fully understand how this item works by checking for any datasheets (not provided with the item), to enable the product to be used within your application / project.
5) VERY IMPORTANT >> Do not make ANY permanent connections. Please test the item BEFORE making any permanent connections e.g. soldering to the item. Please ensure you have the means to test the item WITHOUT applying ANY solder to the item. If an item has any solder applied I will NOT accept any return.
6) When upgrading to 1st class post, (if the option is available), please note this is sent via Royal Mail and is not a guaranteed next day service. If you need a 48hr service please select 48hr delivery at extra cost. This will be sent via Royal Mail or courier. I do not offer a 24hr service. No weekend or public bank holiday deliveries.
7) We attempt to send out all orders received before 10.00am. This excludes weekends and public holidays.
8) Customers placing multiple orders. – I may ship all the orders as one, please do not ask for a refund of shipping cost after you have placed your orders. Please do not place your orders if you want a refund of shipping cost.
9) Some items may have a “Warranty Void if removed” sticker, please DO NOT tamper or remove these stickers. I will not accept any rertuns with tampered or removed sticker. Some buyers have tried to send back items that I have not supplied.

**** Important note **** Some sellers claim the stock is in the UK, please be careful, the seller is often in China and sends the item to a UK agent who then forwards the item on with a UK stamp. Check where the seller is located not just the item location. All my items are physically with me, here in the UK and I offer a quick delivery and communication within the UK.

During busy periods there maybe a delay in delivering your package by Royal Mail. I apologies in adavnce for any inconvenience but would like to point this out before you place your order.