Wago Connectors Cable 773 Series 773-102 773-173 773-104 773-106 773-108

£2.75£50.59

 

Wago Connectors 773-102 773-173 773-104 773-106 773-108

Wago 222 Series connectors – Various Pack sizes Available

Applications

– Low voltage lighting system
– HVAC control circuit
– Junction boxes in wall or ceiling
– Mobile homes

Wago 773 Junction Box Push Wire Connectors

Available in 2, 4, 6 and 8 pole, these colour coded connectors are
suitable for 0.75mm to 2.5mm solid and 1.5mm to 2.5mm stranded cables.
The new 3 pole version is suitable for solid and stranded cables from
1.5mm to 6mm.

Simply pushing the stripped cable into the connector makes the
connection; the transparent housing, a feature of all the connectors in
the range, provides a visible indication that the cable is secure.

There is a test point in the housing. The cables are removed by holding
the wire and twisting left/right while pulling on the connector, which
means the connector can be re-used. Also available is a fixing carrier
that is designed to secure the connectors into a junction box or onto
DIN rail. The rating is 400V, 24A and 41A for 3 pole version.

773-102

No. of Poles 2
Total number of connection points 2
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 400 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG
Strip length 1 12 mm / 0.47 in
Type of wiring Side-entry wiring
Weight [g] 1.847 g
Width 9.2 mm / 0.362 in
Height 13.1 mm / 0.516 in
Length 19.5 mm / 0.768 in
Safety information 1 In grounded power lines

773-173

Total number of connection points 3
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 400 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 41 A
Connection technology (1) PUSH WIRE®
Solid sizes 1 2.5 … 6 mm² / 14 … 10 AWG
stranded, connectable 1 2.5 … 6 mm² / 14 … 10 AWG
Strip length 1 12 … 13 mm / 0.47 … 0.51 in
Type of wiring Side-entry wiring
Fire load [MJ] 0.115 MJ
Weight [g] 5.752 g
Width 25.6 mm / 1.008 in
Height 14.2 mm / 0.559 in
Length 20.1 mm / 0.791 in
Safety information 1 In grounded power lines

773-104

Total number of connection points 4
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 400 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG
Strip length 1 12 mm / 0.47 in
Type of wiring Side-entry wiring
Fire load [MJ] 0.057 MJ
Weight [g] 2.677 g
Width 13 mm / 0.512 in
Height 13.1 mm / 0.516 in
Length 19.5 mm / 0.768 in
Safety information 1 In grounded power lines

773-106

Total number of connection points 6
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 400 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG
Strip length 1 12 mm / 0.47 in
Type of wiring Side-entry wiring
Weight [g] 4.25 g
Width 18.8 mm / 0.74 in
Height 13.1 mm / 0.516 in
Length 19.5 mm / 0.768 in
Safety information 1 In grounded power lines

773-108

Total number of connection points 8
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 400 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG
stranded, connectable 1 1.5 … 2.5 mm² / 16 … 12 AWG
Strip length 1 12 mm / 0.47 in
Type of wiring Side-entry wiring
Fire load [MJ] 0.098 MJ
Weight [g] 4.605 g
Width 24 mm / 0.945 in
Height 13.1 mm / 0.516 in
Length 19.5 mm / 0.768 in
Safety information 1 In grounded power lines

Product will be supplied loose not in a box

FAQs

Should WAGO connectors be used in an enclosure?
In
order to comply with the requirements of the 16th Edition of the IEE
Wiring Regulations/BS7671, all connectors should be used in a suitable
enclosure of material complying with the relevant glow-wire test
requirements of BS 458-2.1. (Fire hazard testing for electrotechnical
products). This will provide
mechanical protection for the connectors
as well as protection against dust, damp and accidental damage.
Although WAGO connectors are IP20 (finger touch) with Polyamide 6.6
housing for strength and durability.

Do they need to be fixed in an enclosure?
The
junction box connectors do not have to be fixed down in the housing
provided that the cables are secured on their way into the box. However,
fixing provides a more secure and professional looking finish.

Does there need to be strain relief on the cable?
Yes,
there should be strain relief on the cable. This could be the cable
clipped outside the enclosure or cable glands within the enclosure to
prevent the cables being pulled out of the connectors.

I’m used to screw connections – how secure is your clamping system?
The
WAGO Cage Clamp? and PushWire clamping systems guarantee gastight,
maintenance-free connections every time. Our connectors incorporating
these proven technologies have been used in industrial and building
services applications worldwide. The company’s reputation is built on
the high quality and proven performance of our products. For installers,
this ensures complete peace of mind.

How do I release the conductor from the terminal?
All
WAGO connectors are re-usable. PushWire conductors are removed by
pulling the conductor and twisting the connector. Cage Clamp?
connections are released by using a screwdriver or pushbutton/lever
operation.

Do your connectors comply with British Standards?
BSI
recognise and harmonise with IEC 60947, 60998 and 60999. These are
European standards which relate to terminal blocks and connectors. All
WAGO products conform to these standards and other international
requirements.

What other standards do your connectors comply with?
WAGO sells its products worldwide and is therefore in constant contact with testing and approvals houses around the globe.

There’s a small cavity in a ceiling, wall or floor. Can a terminal block be fitted without the need for an additional back box?
Yes.
When installing backless equipment, such as a domestic style luminaire,
it is possible for the enclosure to be formed or completed with
building material considered to be non-combustible when tested to BS
476-4. (Fire tests on building materials and structures.
Non-combustibility tests for materials). Where there is any doubt that
the building material does not meet this standard, the electrical
connections should be shielded from the fabric of the building by a
suitable electrical back-box.

Please read and note the following before ordering:
1) My Shipping is for UK Mainland ONLY. No Scotish Highland, Northern Ireland, Isle of Wight or other Isles. Some areas may incur additional costs, if you are unsure please contact me prior to ordering.
2) Please ensure you have a valid contact phone number, I may pass this number onto the Carrier for delivery. No refund for carriage cost will be offered, if delivery is delayed as a result of no valid contact number being provided.
3) I welcome collection for orders,please select collection on checkout otherwise your order will be despatched. Once your order has been picked and tested if applicable. We will then inform you of a date and time for collection. Please bring your payment card for verification when collecting your order. No order will be released without card verification.
4) I am unable to provide ANY technical support, please ensure you fully understand how this item works by checking for any datasheets (not provided with the item), to enable the product to be used within your application / project.
5) VERY IMPORTANT >> Do not make ANY permanent connections. Please test the item BEFORE making any permanent connections e.g. soldering to the item. Please ensure you have the means to test the item WITHOUT applying ANY solder to the item. If an item has any solder applied I will NOT accept any return.
6) When upgrading to 1st class post, (if the option is available), please note this is sent via Royal Mail and is not a guaranteed next day service. If you need a 48hr service please select 48hr delivery at extra cost. This will be sent via Royal Mail or courier. I do not offer a 24hr service. No weekend or public bank holiday deliveries.
7) We attempt to send out all orders received before 10.00am. This excludes weekends and public holidays.
8) Customers placing multiple orders. – I may ship all the orders as one, please do not ask for a refund of shipping cost after you have placed your orders. Please do not place your orders if you want a refund of shipping cost.
9) Some items may have a “Warranty Void if removed” sticker, please DO NOT tamper or remove these stickers. I will not accept any rertuns with tampered or removed sticker. Some buyers have tried to send back items that I have not supplied.

**** Important note **** Some sellers claim the stock is in the UK, please be careful, the seller is often in China and sends the item to a UK agent who then forwards the item on with a UK stamp. Check where the seller is located not just the item location. All my items are physically with me, here in the UK and I offer a quick delivery and communication within the UK.

During busy periods there maybe a delay in delivering your package by Royal Mail. I apologies in adavnce for any inconvenience but would like to point this out before you place your order.