Buyhere22, 26 Somers Road, Rugby, CV22 7DH

Wago Connectors Cable 2273-202 2273-203 2273-204 2273-205 2273-208 Full Set Case

£36.79

3 in stock

 

 

Wago 2273 series

Ideal set of 2273 all in one handy case, you will receive the following

Hand Carry Case
2273-202 * 40
2273-203 * 50
2273-204 * 50
2273-205 * 40
2273-208 * 20

Tech Specs

2273-202

Total number of connection points 2
Total number of potentials 1
Pollution degree (1) 2
Rated voltage EN (1) [V] 450 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Number of connection points (1) 2
Solid sizes 1 0.5 … 2.5 mm² / 18 … 14 AWG
Strip length 1 11 mm / 0.43 in
Strip length from 1 [mm] 11 mm
Strip length up to (1) [mm] 11 mm
Type of wiring Side-entry wiring
Fire load [MJ] 0.014 MJ
Weight [g] 0.713 g
Width 10 mm / 0.394 in
Height 5.8 mm / 0.228 in
Length 16.7 mm / 0.657 in
Safety information 1 In grounded power lines

2273-203

Total number of connection points 3
Total number of potentials 1
Pollution degree (1) 2
Rated voltage EN (1) [V] 450 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Number of connection points (1) 3
Solid sizes 1 0.5 … 2.5 mm² / 18 … 14 AWG
Strip length 1 11 mm / 0.43 in
Strip length from 1 [mm] 11 mm
Strip length up to (1) [mm] 11 mm
Type of wiring Side-entry wiring
Fire load [MJ] 0.019 MJ
Weight [g] 1.017 g
Width 14 mm / 0.551 in
Height 5.8 mm / 0.228 in
Length 16.7 mm / 0.657 in
Safety information 1 In grounded power lines

2273-204

Total number of connection points 4
Total number of potentials 1
Color gray
Pollution degree (1) 2
Rated voltage EN (1) [V] 450 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Number of connection points (1) 4
Solid sizes 1 0.5 … 2.5 mm² / 18 … 14 AWG
Strip length 1 11 mm / 0.43 in
Strip length from 1 [mm] 11 mm
Strip length up to (1) [mm] 11 mm
Type of wiring Side-entry wiring
Fire load [MJ] 0.025 MJ
Weight [g] 1.3 g
Width 18 mm / 0.709 in
Height 5.8 mm / 0.228 in
Length 16.7 mm / 0.657 in
Safety information 1 In grounded power lines

2273-205

Total number of connection points 5
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 450 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Number of connection points (1) 5
Solid sizes 1 0.5 … 2.5 mm² / 18 … 14 AWG
Strip length 1 11 mm / 0.43 in
Strip length from 1 [mm] 11 mm
Strip length up to (1) [mm] 11 mm
Type of wiring Side-entry wiring
Fire load [MJ] 0.03 MJ
Weight [g] 1.581 g
Width 22 mm / 0.866 in
Height 5.8 mm / 0.228 in
Length 16.7 mm / 0.657 in
Safety information 1 In grounded power lines

2273-208

Total number of connection points 8
Total number of potentials 1
Color transparent
Pollution degree (1) 2
Rated voltage EN (1) [V] 450 V
Rated surge voltage (1) [kV] 4 kV
Nominal current [A] 24 A
Connection technology (1) PUSH WIRE®
Number of connection points (1) 8
Solid sizes 1 0.5 … 2.5 mm² / 18 … 14 AWG
Strip length 1 11 mm / 0.43 in
Strip length from 1 [mm] 11 mm
Strip length up to (1) [mm] 11 mm
Type of wiring Side-entry wiring
Fire load [MJ] 0.039 MJ
Weight [g] 2.17 g
Width 18 mm / 0.709 in
Height 10.4 mm / 0.409 in
Length 16.7 mm / 0.657 in
Safety information 1 In grounded power lines

This Product will be supplied in a carry case box

FAQs

Should WAGO connectors be used in an enclosure?
In
order to comply with the requirements of the 16th Edition of the IEE
Wiring Regulations/BS7671, all connectors should be used in a suitable
enclosure of material complying with the relevant glow-wire test
requirements of BS 458-2.1. (Fire hazard testing for electrotechnical
products). This will provide
mechanical protection for the connectors
as well as protection against dust, damp and accidental damage.
Although WAGO connectors are IP20 (finger touch) with Polyamide 6.6
housing for strength and durability.

Do they need to be fixed in an enclosure?
The
junction box connectors do not have to be fixed down in the housing
provided that the cables are secured on their way into the box. However,
fixing provides a more secure and professional looking finish.

Does there need to be strain relief on the cable?
Yes,
there should be strain relief on the cable. This could be the cable
clipped outside the enclosure or cable glands within the enclosure to
prevent the cables being pulled out of the connectors.

I’m used to screw connections – how secure is your clamping system?
The
WAGO Cage Clamp? and PushWire clamping systems guarantee gastight,
maintenance-free connections every time. Our connectors incorporating
these proven technologies have been used in industrial and building
services applications worldwide. The company’s reputation is built on
the high quality and proven performance of our products. For installers,
this ensures complete peace of mind.

How do I release the conductor from the terminal?
All
WAGO connectors are re-usable. PushWire conductors are removed by
pulling the conductor and twisting the connector. Cage Clamp?
connections are released by using a screwdriver or pushbutton/lever
operation.

Do your connectors comply with British Standards?
BSI
recognise and harmonise with IEC 60947, 60998 and 60999. These are
European standards which relate to terminal blocks and connectors. All
WAGO products conform to these standards and other international
requirements.

What other standards do your connectors comply with?
WAGO sells its products worldwide and is therefore in constant contact with testing and approvals houses around the globe.

There’s a small cavity in a ceiling, wall or floor. Can a terminal block be fitted without the need for an additional back box?
Yes.
When installing backless equipment, such as a domestic style luminaire,
it is possible for the enclosure to be formed or completed with
building material considered to be non-combustible when tested to BS
476-4. (Fire tests on building materials and structures.
Non-combustibility tests for materials). Where there is any doubt that
the building material does not meet this standard, the electrical
connections should be shielded from the fabric of the building by a
suitable electrical back-box.

Please read and note the following before ordering:
1) My Shipping is for UK Mainland ONLY. No Scotish Highland, Northern Ireland, Isle of Wight or other Isles. Some areas may incur additional costs, if you are unsure please contact me prior to ordering.
2) Please ensure you have a valid contact phone number, I may pass this number onto the Carrier for delivery. No refund for carriage cost will be offered, if delivery is delayed as a result of no valid contact number being provided.
3) I welcome collection for orders,please select collection on checkout otherwise your order will be despatched. Once your order has been picked and tested if applicable. We will then inform you of a date and time for collection. Please bring your payment card for verification when collecting your order. No order will be released without card verification.
4) I am unable to provide ANY technical support, please ensure you fully understand how this item works by checking for any datasheets (not provided with the item), to enable the product to be used within your application / project.
5) VERY IMPORTANT >> Do not make ANY permanent connections. Please test the item BEFORE making any permanent connections e.g. soldering to the item. Please ensure you have the means to test the item WITHOUT applying ANY solder to the item. If an item has any solder applied I will NOT accept any return.

6) When upgrading to 1st class post, (if the option is available), please note this is sent via Royal Mail and is not a guaranteed next day service. If you need a 48hr service please select 48hr delivery at extra cost. This will be sent via Royal Mail or courier. I do not offer a 24hr service. No weekend or public bank holiday deliveries.
7) We attempt to send out all orders received before 10.00am. This excludes weekends and public holidays.

8) Customers placing multiple orders. – I may ship all the orders as one, please do not ask for a refund of shipping cost after you have placed your orders. Please do not place your orders if you want a refund of shipping cost.
9) Some items may have a “Warranty Void if removed” sticker, please DO NOT tamper or remove these stickers. I will not accept any rertuns with tampered or removed sticker. Some buyers have tried to send back items that I have not supplied.

**** Important note **** Some sellers claim the stock is in the UK, please be careful, the seller is often in China and sends the item to a UK agent who then forwards the item on with a UK stamp. Check where the seller is located not just the item location. All my items are physically with me, here in the UK and I offer a quick delivery and communication within the UK.

During busy periods there maybe a delay in delivering your package by Royal Mail. I apologies in adavnce for any inconvenience but would like to point this out before you place your order.